96 well cometchip system (Bio-Techne corporation)
Structured Review

96 Well Cometchip System, supplied by Bio-Techne corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/96+well+cometchip+system/pmc09469923-251-1-4?v=Bio-Techne+corporation
Average 86 stars, based on 1 article reviews
Images
1) Product Images from "A high-throughput 384-well CometChip platform reveals a role for 3-methyladenine in the cellular response to etoposide-induced DNA damage"
Article Title: A high-throughput 384-well CometChip platform reveals a role for 3-methyladenine in the cellular response to etoposide-induced DNA damage
Journal: NAR Genomics and Bioinformatics
doi: 10.1093/nargab/lqac065
Figure Legend Snippet: Development of the 384-well CometChip. ( A ) Top left: a 96-well CometChip former (Bio-Techne); Top right: an outline image of the entire 96-well CometChip; Bottom left: an image of comets in four wells of a 96-well CometChip; Bottom right: images of comets within one well of a 96-well CometChip. ( B ) Top left: a 384-well CometChip former; Top right: an outline image of the entire 384-well CometChip; Bottom left: an image of comets in 16 wells of a 384-well CometChip; Bottom right: images of comets within one well of a 384-well CometChip.
Techniques Used:
Figure Legend Snippet: Comparison of the sensitivity of the 384-well CometChip platform to that of the 96-well CometChip platform for DNA damage evaluation. ( A ) TK6 cells were treated with etoposide (0–10 μM), with a 2 μM ascendance, for 30 min and the level of DNA damage was analyzed using either the 384-well platform or the 96-well platform. The number of comets within each well in a 96-well CometChip or in a 384-well CometChip is shown. Each dot represents the number of the counted comets in a well of the 96-well or 384-well CometChip. ( B ) The DNA damage (%Tail DNA) measured in cells after etoposide exposure was quantified by the 96-well CometChip assay or the 384-well CometChip assay. Each dot represents the average DNA damage level (%Tail DNA) of a well of the 96-well CometChip or the 384-well CometChip. ( C ) TK6 cells were treated with etoposide (10 μM) for 30 min or treated with etoposide (10μM) for 30 min followed by a washout of etoposide by 10ml 1x PBS then re-seeded the cells back into growth medium to repair DNA damage induced by etoposide for 15, 30, 45 or 75 min. Subsequently, the DNA damage (%Tail DNA) was quantified by the 384-well CometChip assay. Each dot represents the average DNA damage level (%Tail DNA) of a well of the 384-well CometChip. DMSO treatment was used as the negative control.
Techniques Used: Comparison, Negative Control
Figure Legend Snippet: 96-well CometChip assay validation of the 3-MA increase in the etoposide-induced DNA damage. ( A ) TK6 cells were pre-treated with the top 5 kinase inhibitor hits for 30 min followed by etoposide (2 or 4 μM) for an additional 30 min. The DNA damage was analyzed using a 96-well platform (** P < 0.01, *** P < 0.001). ( B ) TK6 cells were pre-treated with 3-MA at 10 or 20 μM for 1 or 2 h followed by etoposide (2 μM) for an additional 30 min. The DNA damage was analyzed using a 96-well platform (**** P < 0.0001).
Techniques Used: